BYN
Cable multicore with polyvinylchloride isolation and a cover of kgvva on tu 16-705.259-82 in Schuchin online-store Shchuchinskij zavod Avtoprovod, OAO | Buy Cable multicore with polyvinylchloride isolation and a cover of KGVVA on TU 16-705.259-82 Schuchin (Belarus) | Shchuchinskij zavod Avtoprovod, OAO : Allbiz
Premium Business
Reviews: 2
Cable multicore with polyvinylchloride isolation and a cover of KGVVA on TU 16-705.259-82
  • Cable multicore with polyvinylchloride isolation and a cover of KGVVA on TU 16-705.259-82

Cable multicore with polyvinylchloride isolation and a cover of KGVVA on TU 16-705.259-82

In stock
Brand:Щучинский завод Автопровод, ОАО
Country of manufacture:Belarus
Payment:
Shipping:
Description

Cables multicore with polyvinylchloride isolation and a cover

Cables are flexible automobile

APPOINTMENT

Cables multicore with polyvinylchloride isolation and a cover intended for accession of electric equipment to an electric network of a direct current of cars with a rated voltage up to 28 V.

- the KGVVA brands - cables flexible with polyvinylchloride isolation and a cover;

- the KGVVAM brands - cables flexible with polyvinylchloride isolation and a cover with the reduced radial thickness of isolation.

DESIGN

CONDUCTING VEIN - copper, multiwire.

ISOLATION - PVC plastic compound. The isolated veins have to be various flowers. For the KGVVAM cable - thin-walled isolation.

TWIST - the isolated veins are twisted. Parallel laying of veins in twin-core cables is allowed.

COVER - PVC plastic compound.

THE NUMBER OF VEINS - 2, 3, 4, 7, 10, 12, 14, 19.

NOMINAL SECTION, mm ²: 0,75; 1,0; 1,5.

The number and nominal section of conducting veins, the nominal external size of cables are specified in the table:

Number and nominal section of veins, mm2 Nominal external size of cables, mm Settlement weight is 1 km of a cable, kg
KGVVA KGVVAM
KGVVA KGVVAM HL1 U1, T1 HL1 U1, T1
2×0,75 6,1 4,9 38 40 29 31
2×0,75 * 3,7×6,1 3,1×4,9 36 38 27 29
3×0,75 6,5 5,2 51 53 39 41
4×0,75 7,9 6,4 77 81 60 63
5×0,75 8,6 7,0 92 97 71 75
7×0,75 9,4 7,5 119 125 92 96
10×0,75 11,8 9,3 165 173 128 133
12×0,75 12,1 9,6 191 200 147 153
14×0,75 12,7 10,0 218 227 168 174
19×0,75 18,9 11,1 284 296 219 227
2×1,0 6,3 5,1 42 45 34 35
2×1,0 * 3,7×6,3 3,2×5,1 40 42 32 33
3×1,0 6,7 5,4 58 60 46 48
4×1,0 8,1 6,7 86 91 69 72
5×1,0 8,9 7,2 103 108 82 86
7×1,0 9,6 7,8 135 141 108 112
10×1,0 12,1 9,7 188 196 150 155
12×1,0 12,5 10,0 218 227 174 180
14×1,0 13,1 10,5 250 259 199 205
19×1,0 14,6 11,6 327 339 261 268
2×1,5 6,9 6,1 54 57 48 50
2×1,5 * 4,1×6,9 3,7×6,1 52 55 46 48
3×1,5 7,3 6,4 75 78 66 69
4×1,5 8,8 7,9 110 115 97 101
5×1,5 9,7 8,6 133 139 118 122
6×1,5 10,5 9,3 156 163 138 143
7×1,5 10,5 9,3 176 183 155 161
8×1,5 11,3 10,0 199 207 176 182
10×1,5 13,3 11,7 246 255 218 225
12×1,5 13,7 12,1 287 297 254 262
14×1,5 14,4 12,7 330 341 291 300
19×1,5 16,1 18,9 435 448 384 394
* - the isolated veins are laid in parallel
The note - settlement weight is specified as a reference material

TECHNICAL CHARACTERISTICS

Electric resistance of a conducting vein to a direct current at a temperature 20Сº has to be no more:

- for the section of 0,75 mm2 - 26,0 Ohms

- for the section of 1,0 mm2 - 19,5 Ohms

- for the section of 1,5 mm2 - 13,3 Ohms

Cables are steady against sign-variable deformations of a bend.

Cables are intended for operation at temperatures:

- from minus 40 to plus 70 °C for execution of U1;

- from minus 30 to plus 70 °C for execution of T1;

- from minus 60 to plus 70 °C for execution of HL1 in the conditions of assembly and operational bends with a radius not less than 15 diameters of a cable.

Cables are resistant to influence of mineral oil, gasoline and diesel fuel.

Cables do not extend burning at single laying.

90% resource of cables not less than 450 thousand km of run of the car

Construction length of cables - not less than 100 m, is allowed delivery by lengths not less than 20 m in number of no more than 20% of the total length of party.

The minimum operating time of cables - 20000 h.

Average service life of cables - 10 years.

Characteristics:
Brand:Щучинский завод Автопровод, ОАО
Country of manufacture:Belarus
Conductor material:Copper
Wire Gauge: - AWG
Cut:Round
Insulation:Plastic
Information is up-to-date: 14.03.2019
Shipping method
Payment method

Read more

Unbelievable price on Cable multicore with polyvinylchloride isolation and a cover of KGVVA on TU 16-705.259-82 in Schuchin (Belarus) company Shchuchinskij zavod Avtoprovod, OAO.
LiveInternet